A Fully Automated Measuring Station for the Calibration of Voltage Transducers |
---|
Antonio Delle Femine, Carmine Landi, Mario Luiso |
- Abstract:
- Power quality analyses in the last years has assumed more and more heaviness in industrial environments, due to the presence of non-linear loads: they require suitable and precise measuring instrumentation. Nevertheless, while there are lots of power quality standards fixing high frequency limits for harmonic analyses, there is a lack of standards concerning transducers calibration at amplitude and frequency different from the rated ones. Therefore in this paper a fully automated measuring station for the calibration of voltage transducers in wide amplitude and frequency ranges is discussed. As an application, the results of the calibration of a commercial transducer are presented: they are used to implement a time-domain procedure for real-time correction of the frequency response of the calibrated transducer.
- Download:
- IMEKO-TC4-2007-067.pdf
- DOI:
- -
- Event details
- IMEKO TC:
- TC4
- Event name:
- TC4 Symposium 2007
- Title:
- XVth IMEKO TC4 International Symposium on Novelties in Electrical Measurements and Instrumentation (together with 12th IMEKO TC4 Workshop on ADC Modelling and Testing)
- Place:
- Iasi, ROMANIA
- Time:
- 19 September 2007 - 21 September 2007