Skip to main content

FLOWMETRING AND ACOUSTIC STUDY OF A GAS FLOWRATE LIMITER 

Fares Ben Rayana

Abstract

The CRIGEN had realized a wide experimental study on gas flowrate limiter used on compact meter station for measuring gas flow at variable pressure. This device is used to control and limit, for a specified pressure, the flowrate of the meter station. It is a perforated plate with a constant holes size. Each hole is functioning as a sonic nozzle. The number and size of the hole are defined by the meter station maximal flowrate. This paper shows that the flowrate limiter geometry (the hole size, the ratio plate thickness/hole size and the number of holes) can be changed without affecting the meter station characteristics: flowrate range, residual pressure loss. In the other hand the noise produced by this device can be decreased by reducing the hole size.

Keywords
gas flowrate limiter, acoustic
Download
IMEKO-TC9-2013-068.pdf
DOI
-
IMEKO TC
TC9 - Flow Measurement

Event details

Event
FLOMEKO 2013
Technical Committee
TC9
Place
Paris, FRANCE
Time
24 September 2013 - 26 September 2013
Website
http://www.flomeko2013.fr

Back to the proceedings