EXPERIMENTAL VALIDATION OF SOLENOID MAGNETIC CENTRE MEASUREMENT BY VIBRATING WIRE SYSTEM

P. Arpaia, C. Petrone, L. Walckiers

Abstract

A method to measure the magnetic axis position of a solenoid magnet by means of a vibrating wire is proposed. The method allows the magnetic axis to be found in spite of the low transversal field. The experimental results of the magnetic axis measurements on a prototype solenoid magnet of the linear accelerator for the low energy beam transport line at CERN are illustrated.

Keywords
electromagnetic fields, vibration measurement, measurement science, force measurement
Download
IMEKO-WC-2012-TC4-O10.pdf
DOI
-
IMEKO TC
TC4 - Measurement of Electrical Quantities

Event details

Event
XX IMEKO World Congress
Place
Busan, REPUBLIC of KOREA
Time
9 September 2012 - 12 September 2012
Website
http://imeko2012.kriss.re.kr