Skip to main content

IMPROVED DYNAMIC RANGE FOR MULTI-TONE SIGNAL USING MODEL-BASED PRE-DISTORTION

Carolina Luque A., Niclas Björsell

Abstract

Some test and measurement applications require higher dynamic range for multi-tone signals than a signal generator can generate. Moreover, for other applications it can be interesting to improve the performance of a “low cost” signal generator. The spectral purity of generated signals can be improved by using pre-distorted base-band signals. In this paper, a dynamic grey-box model is described. A pre-distorter is used in order to improve the dynamic range. The results, which are based on measurements, show an improved dynamic range for a three-tone signal of approximately 9 dB and an improved ACPR of 5 dB for a WCDMA signal.

Download
IMEKO-IWADC-2008-012.pdf
DOI
-
IMEKO TC
TC4 - Measurement of Electrical Quantities

Event details

Event
IWADC 2008
Technical Committee
TC4
Place
Florence, ITALY
Time
22 September 2008 - 24 September 2008
Website
http://www.imeko2008.org/

Back to the proceedings