Skip to main content

REALIZATION OF THE INDUCTANCE STANDARD AT CEM

Y. A. Sanmamed, A. Sánchez, K. Schweiger, J. Díaz de Aguilar, R. Caballero,M. Neira
  • Abstract:
    Inductance has been realized at Spanish Centre of Metrology (CEM) by means of a modified coaxial Maxwell-Wien bridge. This method ensures inductance traceability from the SI unit of capacitance and establishes the value of the CEM’s set of 10 mH standard inductors at the frequency of 1 kHz.
  • Keywords:
    Inductance, capacitance, resistance, impedance bridge
  • DOI:
    _unreg_tc4-2011.030

Event details:

[EVENTDETAILS]
  • IMEKO TC:
    TC4
  • Event name:
    TC4 Symposium 2011
  • Title:

    XVIIIth IMEKO TC4 International Symposium on Measurement of Electrical Quantities (part of Metrologia2011, together with IX International Congress on Electrical Metrology - IX SEMETRO)

  • Place:
    Natal, BRAZIL
  • Time:
    27 September 2011 - 30 September 2011