Skip to main content

On Measurement Uncertainty of a Vortex Flowmeter

Jiun-Jih J. Miau, Chen-Fan Yeh, Chih-Chung Hu, Jung-Hua Chou
  • Abstract:
    Measurement uncertainty of a T-shaped flowmeter was examined with a gas flow calibration facility, for Reynolds numbers, Red, in a range of 2.56 × 104 - 1.56 × 105. The total uncertainty interval of the Strouhal values deduced from a Fourier spectral analysis was ±0.745 %, and the linearity of the data was ±1.78 %. Meanwhile, a scheme based on pulses counting in reference to the analog signals measured gave the total uncertainty interval of the meter factor as ±0.568 %, with the linearity ±1.89 %.
  • Keywords:
    Vortex flowmeter, Measurement uncertainty
  • DOI:
    _unreg_tc9-2004.048

Event details:

[EVENTDETAILS]
  • IMEKO TC:
    TC9
  • Event name:
    FLOMEKO 2004
  • Title:
    12th Conference on Flow Measurement
  • Place:
    Beijing, CHINA
  • Time:
    14 September 2004 - 17 September 2004