S. Dlamini, C. Gouws, A. Cardenas Moctezuma, J. C. Torres-Guzman
-
Abstract:This paper details a force bilateral comparison between the National Metrology Institute of South Africa (NMISA) and Centro Nacional de Metrologia (CENAM, Mexico). A single 50 kN Force Transducer was used as the artefact. Measurements were conducted in compression mode in the range of 10 kN to 50 kN. The characteristics of the two standard machines used and the procedure of the comparison are briefly discussed. The values of measurements and the associated uncertainties for each laboratory are reported as well as the degree of equivalence between the two national force laboratories.
-
Keywords:force, bilateral comparison, force standard machine
-
Download:
-
DOI:_unreg_tc3-2017.052
Event details:
[EVENTDETAILS]
-
IMEKO TC:TC3
-
Event name:TC3 Conference 2017 - Measurement facing new challenges!
-
Title:
23rd Conference on the Measurement of Force, Mass and Torque (together with 4th TC22 Conference on Vibration Measurement and 13th TC5 Conference on the Measurement of Hardness)
-
Place:Helsinki, FINLAND
-
Time:30 May 2017 - 1 June 2017