Skip to main content

Experimental Investigation on Zero Drift Effect in Coriolis Mass Flowmeters

Li-Jun Wang, Liang Hu, Xin Fu, Peng Ye
  • Abstract:
    It is claimed that Coriolis mass flowmeter (CMF) can accurately measure the mass flow-rate without being effected by temperature. However, evidences from practical industry applications show that sometimes CMFs still suffer so-called "zero drift (ZD) effect": the origin of the flowmeter (reading at zero flow) varies as temperature changing. In this paper, series of experiments are carried out to systematically examine and analyze the performance of a Narrowed-U-CMF in a temp- changing environment. Based on the results of these experiments, possible reasons causing the ZD effect are analyzed, which provides a base for further solutions of the ZD effect.
  • Keywords:
    Coriolis Mass Flowmeter, Zero drift effect
  • DOI:
    _unreg_tc9-2010.076

Event details:

[EVENTDETAILS]
  • IMEKO TC:
    TC9
  • Event name:
    FLOMEKO 2010
  • Title:

    15th Conference on Flow Measurement

  • Place:
    Taipei, CHINESE TAIPEI (economy)
  • Time:
    12 October 2010 - 14 October 2010