Search Proceedings
Who we are
Experimental Investigation on Zero Drift Effect in Coriolis Mass Flowmeters
Li-Jun Wang, Liang Hu, Xin Fu, Peng Ye
-
Abstract:It is claimed that Coriolis mass flowmeter (CMF) can accurately measure the mass flow-rate without being effected by temperature. However, evidences from practical industry applications show that sometimes CMFs still suffer so-called "zero drift (ZD) effect": the origin of the flowmeter (reading at zero flow) varies as temperature changing. In this paper, series of experiments are carried out to systematically examine and analyze the performance of a Narrowed-U-CMF in a temp- changing environment. Based on the results of these experiments, possible reasons causing the ZD effect are analyzed, which provides a base for further solutions of the ZD effect.
-
Keywords:Coriolis Mass Flowmeter, Zero drift effect
-
Download:
-
DOI:_unreg_tc9-2010.076
Event details:
[EVENTDETAILS]
-
IMEKO TC:TC9
-
Event name:FLOMEKO 2010
-
Title:
15th Conference on Flow Measurement
-
Place:Taipei, CHINESE TAIPEI (economy)
-
Time:12 October 2010 - 14 October 2010