Search Proceedings
Who we are
Dynamic Calibration of Fatigue Test Machines Using a Dynamic Calibration Device
Rafael S. Oliveira, Renato R. Machado, Claudio A. Koch, Luiz C. Cabral de Freitas, Wellington G. Fernandes, Antonio L. Gama
-
Abstract:This paper describes the practical application of method B of the ISO 4965-1 standard for the dynamic force calibration of a fatigue test machine. The experiment focuses on detailing the main proceedings involved such as the load series, the frequency sweep range and the data acquisition and processing parameters applied to the Dynamic Calibration Devices (DCDs), used with different compliances. The calibration results are shown and a discussion is proposed.
-
Keywords:ISO 4965-1, dynamic force calibration, dynamic traceability, fatigue test machines
-
Download:
-
DOI:_unreg_tc3-2017.024
Event details:
[EVENTDETAILS]
-
IMEKO TC:TC3
-
Event name:TC3 Conference 2017 - Measurement facing new challenges!
-
Title:
23rd Conference on the Measurement of Force, Mass and Torque (together with 4th TC22 Conference on Vibration Measurement and 13th TC5 Conference on the Measurement of Hardness)
-
Place:Helsinki, FINLAND
-
Time:30 May 2017 - 1 June 2017