Search Proceedings
Who we are
ACCURACY ENHANCEMENT OF A COMBINED V/Z CLAMP-ON ULTRASONIC FLOW
Sejong Chun, Byung-Ro Yoon, Woong Kang, Hyu-Sang Kwon
-
Abstract:Ultrasonic flow metering with clamp-on type transducers is a promising method when portability in flow metering is necessary. Nevertheless, the clamp-on ultrasonic flow meter has low measurement accuracy as flow speed in the pipe decreases. If the two types of clamp-on ultrasonic flow paths, namely, Z-shaped and V-shaped ultrasonic paths, are combined, measurement accuracy can be increased because the metering output becomes robust. In the present study, the measurement accuracy of the combined clamp-on ultrasonic flow meter was within ±2 % at 50 m3/h, which was smaller than those of the Z-shaped and the V-shaped clamp-on ultrasonic flow meters at the same flow rate. This can provide an advantage for water resource management because a general guideline for the water resource management is less than ±2 %.
-
Keywords:clamp-on ultrasonic flow meter, V-shaped, Z-shaped
-
Download:
-
DOI:_unreg_tc9-2013.083
Event details:
[EVENTDETAILS]
-
IMEKO TC:TC9
-
Event name:FLOMEKO 2013
-
Title:
16th International Flow Measurement Conference
-
Place:Paris, FRANCE
-
Time:24 September 2013 - 26 September 2013