Skip to main content

THE PERFORMANCE OF A MODIFIED ELECTROMAGNETIC FLOWMETER WHEN ABUTTED TO A SMALLER MISALIGNED UPSTREAM DIAMETER PIPE

C. J. Bates
  • Abstract:
    Electromagnetic flowmeters are today widely used for industrial flow measurement. For industrial users, due to physical constraints, the installation recommendations contained in national and international standards may not be achievable. The actual installation then results in the flowmeter being exposed to velocity profiles which are not fully developed, and do not accord with the situation for which the meter was designed and calibrated. The influence of a smaller upstream diameter pipe together with pipeline misalignment, when abutted to an electromagnetic flowmeter, is discussed.
  • Keywords:
    electromagnetic flowmeters, laser doppler anemometry, misalignment effects
  • DOI:
    _unreg_tc9-2000.019

Event details:

[EVENTDETAILS]
  • IMEKO TC:
    TC9
  • Event name:
    FLOMEKO 2000
  • Title:
    10th Conference on Flow Measurement
  • Place:
    Salvador, Bahia, BRAZIL
  • Time:
    4 June 2000 - 8 June 2000